image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Hotel Info 
 Abstracts 
 Scientific Program 
 Social Program 
 Exhibition 
 Contact Us 
       XXIV Annual Congress of the Iranian Society of Ophthalmology        بـیــست و چهارمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Objective and Subjective Assessing Efficacy of the Rewetting Comfort Drop in Eyes Wearing Silicone Hydrogel Contact Lenses
Author(s): Amir Asharlous MSc, Ali Mirzajani Ph.D, Ebrahim Jafarzadehpur Ph.D
Presentation Type: Poster
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Amir Asharlous
Affiliation :(optional) iran university of medical sciences
E mail: asharlous.a@iums.ac.ir
Phone: 021-65519302
Mobile: 09128435537
Purpose:

To investigate the effect of the rewetting drop on optical quality, tear film stability and subjective symptoms in individuals wearing silicone hydrogel contact lens.

Methods:

Pre-lens Tear Deformation Time (PL-TDT), Root-Mean-Square (RMS) of Low Order Aberrations (LOA) and High Order Aberrations (HOA), individual twelve Zernike coefficients and subjective symptoms were assessed in 43 volunteers (Mean age 19.58 ±1.63, 86 eyes) at 6 hours after inserting the contact lens and then at 60 min after instilling the rewetting drop (Comfort Drops, AVIZOR, Madrid-Spain).SPSS software (Statistical Package for the Social Sciences) version 16 was utilized for statistical analyses.

Results:

PL-TDT, LOA-RMS and HOA-RMS values measured before drop instillation were not significantly different with those measured after drop. None of the Zernike coefficients were significantly differ after rewetting drop instillation. Statistically significant decrement in both frequency and severity values of blurry vision, dryness, discomfort, burning, itching, foreign body sensation, excessive blinking and lacrimation were seen after drop instillation (P values <0.05).

Conclusion:

Our results showed that the rewetting drop did not prolongedly improve the tear film stability and optical quality in the silicone hydrogel contact lens wearers, but they experience a subjective satisfaction.

Attachment: 5870.pptx





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        ارسال مقالات
        برنامه کنگره
        نمایشگاه
        تماس با ما
        جستجوی سخنران
        برگزیدگان جشنواره فیلم
        برگزیدگان جشنواره عکس
 
Last News

  - بـیــست و چهارمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران