Purpose:
|
To present a case with repeated episodes of flat anterior chamber (AC) after Ahmed valve implantation, and to suggest a simple suturing procedure to manage these recurrences.
|
Methods:
|
After Ahmed value implantation, anterior chamber became flattened spontaneously on postoperative day one. Therefore, we filled the AC with air at the first attempt but this procedure was failed a day later. Then, we filled the AC with an ocular viscoelastic device. Because of failure of these procedures to keep the AC formed, we hypothesized that it may be a malfunctioned valve. Therefore, we inserted a 5-0 Nylon in Ahmed tube through AC and fixed it to the subconjunctiva two days after the second procedure.
|
Results:
|
Anterior chamber remained deep and anterior chamber shallowing did not occur despite removing the suture 2 weeks after the insertion. The IOP was well controlled with a functional filtering device at the last follow–up visit 4 months after the surgery.
|
Conclusion:
|
spontaneous episodes of flat AC after Ahmed valve implantation in an eye can be well managed by inserting a removable suture into the Ahmed valve tube.
|