image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Hotel Info 
 Abstracts 
 Scientific Program 
 Social Program 
 Exhibition 
 Contact Us 
       XXIV Annual Congress of the Iranian Society of Ophthalmology        بـیــست و چهارمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Correlation of corneal elevation and difference elevation measured by Scheimpflug corneal imaging with severity of keratoconus
Author(s): Reza Soltani Moghadam , Mohamad Javad Mohamadi ,Soheil Soltanipour , Heidar Veisi
Presentation Type: Poster
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Reza Soltani moghaddam
Affiliation :(optional) Eye research center , Guilan University of Medical Sciences, Rasht, Iran
E mail: Reza_sm76@yahoo.com
Phone: 01317278499
Mobile: 09123602196
Purpose:

To evaluate the correlation of corneal elevation and difference elevation with severity of keratoconus

Methods:

: 90 eyes of 55 keratoconus patients of different clinical stages were evaluated. Anterior and posterior corneal elevations with both conventional and enhanced best-fit spheres (using rotating Scheimpflug camera) were measured. Front and back difference elevation were extrapolated from difference map of Belin-Ambrosio enhanced ectasia display of the Scheimpflug system. Data from corneal elevations and difference elevations were correlated with maximum keratometry , minimal corneal thickness and severity of keratoconus as assessed by Amsler-Krumiech classification of keratoconus

Results:

There was a significant positive correlation between keratoconus severity and corneal elevations (anterior and posterior elevation measured with both conventional and enhanced best-fit spheres) and also between keratoconus severity and corneal elevation differences (P = .000 and r > .680 for all). Maximum keratometry (K max), Mean keratometry (K m) and all corneal elevations and difference elevations were highly correlated (P = .000 and r > .840 for all). A significant negative correlation was found between minimum corneal thickness and all corneal elevations and difference elevations

Conclusion:

Evaluation of corneal elevation and and difference elevation data obtained from Scheimpflug corneal imaging is useful for grading severity of keratoconus

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        ارسال مقالات
        برنامه کنگره
        نمایشگاه
        تماس با ما
        جستجوی سخنران
        برگزیدگان جشنواره فیلم
        برگزیدگان جشنواره عکس
 
Last News

  - بـیــست و چهارمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران