Title: Intrastromal Corneal Ring Segment Implantation (KeraRing355º) in Patients with central Keratoconus: 3 months follow-up
Author(s): Seyed Aliasghar Mosavi MD,Khosrow Jadidi MD, Farhad Nejat MD ,Leila Janani PhD
Presentation Type: Oral
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Seyed ali asghar Mosavi
Affiliation :(optional) Department of Ophthalmology, Bina Eye Hospital Research Center, Tehran, Iran
E mail: a_a_mosavi@hotmail.com
Phone: 22605915
Mobile: 09352148404
Purpose:

To evaluate the efficacy and safety of Keraring 355º intrastromal corneal ring (ICR; Mediphacos, Belo Horizonte, Brazil) implantation aided by PocketMaker microkeratome (DIOPTEX GmbH, Austria for the treatment of central keratoconus.

Methods:

This study included 15 eyes of 15 patients (mean age, 28.87±6.94 years) with nipple-type keratoconus who underwent ICR implantation (KeraRing355°) using mechanical dissection with the PocketMaker microkeratome. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, topographic findings, safety, efficacy index and adverse events were reported at 3 months postoperatively.

Results:

At the 3-month follow-up visit, there was a statistically significant reduction in the spherical equivalent refractive error (-0.10 [2.4] postoperative versus -2.97[1.74] D preoperative, p=0.027). Mean UCVA (logMAR) improved from 0.8 (0.46) preoperatively to 0.41 (0.24) postoperatively (p=0.006), while mean BSCVA (logMAR) improved from 0.33 (0.18) to 0.29 (0.17, p=0.574).Additionally, the mean K reading decreased by 5.26 D (from 46.93 D to 41.67 D, p=0.001). No intraoperative and postoperative complications were demonstrated in this series of patients.

Conclusion:

The outcomes of the preliminary study show that the ICRS (KeraRing 355º) implantation is an efficient, cost-effective and minimally invasive procedure for improving visual acuity in nipple type keratoconic corneas.

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        ارسال مقالات
        برنامه کنگره
        نمایشگاه
        تماس با ما
        جستجوی سخنران
        برگزیدگان جشنواره فیلم
        برگزیدگان جشنواره عکس
 
Last News

  - بـیــست و چهارمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران